Kichler 15735 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Osvětlení Kichler 15735. Kichler 15735 Manuel d'utilisation Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 2
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Kichler Design Pro LED Under Rail Fixture Installation Instructions
P/N: 15735AZT/BBR/CO, 15736AZT/BBR/CO, 15755AZT/BBR/CO
Dev. No: CP300349AZT/BBR/CO, CP300350AZT/BBR/CO, CP300351AZT/BBR/CO
READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National Electric Code (NEC) and Local code specifications.
Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa, or fountain.
2) This fixture is to be used only with a power unit (transformer) rated a maximum of 300 W (25 AMPS) 15 volts.
3) The 18AWG fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6” (152mm) beneath the surface of the ground. NOTE: If additional Direct Burial
wire is needed, contact your local Kichler® landscape distributor.
• 8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
• 10GAwirecanbepurchasedinlengthof250’(76M),15504-BK.
• 12GAwirecanbepurchasedinlengthsof100’(30M),15501-BK;250’(76M),15502-BK;500’(152M),15505-BK;and
1000’(304M),15506-BK.
5) DO NOT INSTALL under stairs where the tread overhangs the riser less than ¾” [19 mm]
6) Wiringconnectionsmustbemadewithapproved/listedwireconnectiondevice(s)suitablefortheapplication.Donotexceedmanufacturers
wiring combination specifications for size and quantity of conductors.
INSTALLATION OF 15735, 15736, or 15755, IN RAILING, DECK OVER-HANG OR STAIR
(SEE FIG. A)
1) Turn off power.
2) Determine the desired location for the fixture. If using 15717, 15718 or 15719 accessory, please refer to accessory instruction sheet.
3) If desired, a wireway hole can be drilled through the decking fascia or other surface adjacent to the mounting surface.
a. Hold the fixture in the desired mounting location. Mark the location where the wire exits the fixture.
b. Drill hole though surface. (suggested ¼” [6.5 mm] hole)
c. Thread the wire through the hole.
4) Install fixture using #8 wood screws (provided). If screws are difficult to install, mark holes and drill 1/8” pilot holes.
NOTE: DO NOT OVER TIGHTEN SCREWS.
5) Connect fixture wires to main low voltage supply cable using the connector(s) provided.
FIG. A
Date Issued: 6/25/10 IS-15735-CB
WARRANTY
WE WARRANT THE LANDSCAPE PRODUCTS FEATURED IN OUR LANDSCAPE LIGHTING CATALOG (WITH THE EXCEPTION OF LIGHT BULBS) FOR FIVE YEARS AGAINST
DEFECTS IN MATERIALS AND WORKMANSHIP IF IT WAS PROPERLY INSTALLED AND FAILED UNDER NORMAL OPERATING CONDITIONS, PROVIDED IT IS RETURNED TO
THE POINT OF PURCHASE, WHERE IT WILL BE REPAIRED OR, AS IT MAY BE DETERMINED, TO REPLACE THE LANDSCAPE PRODUCT OR PARTS USED ON THAT PRODUCT.
QUIC DISC
WIRING INSTRUCTIONS
Turn off power.
The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are
met:
•Wiringistobeprotectedbyroutingclosetothextureoraccessoryorsecuredtoabuildingstructuresuchashouseordeck.
• 18GAxturewiringistobecutoffsothatitisattachedtotheconnectorwithin6inchesofthextureorbuildingstructure.
• Ifitisnecessarytomaketheconnectionsunderground,thennomorethan6inchesofthe18GAxturewireistobeburied.
The Quic Disc
connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA
supply wire.
Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc
or place the 12 gauge supply wire across the area
marked 12 GA on Quic Disc
.
Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc
. After the wires are in place, connecta the top of the
Quic Disc
to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc
, and the
screw is tightened all the way down.
Thecoppercontactswillautomaticallypiercethewires’insulation.Excess18GAxturewirethatsticksouttheendoftheQuicDisc
is to be cut off.
Make no other wiring connections to the 18 GA fixture wire.
OUTDOOR USE ONLY
DOM ETRE INSTALLE A L’EXTERIEUR
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1

Kichler Design Pro LED Under Rail Fixture Installation InstructionsP/N: 15735AZT/BBR/CO, 15736AZT/BBR/CO, 15755AZT/BBR/CO

Strany 2 - Kichler Design Pro DEL

Kichler Design Pro DELInstructions de montage pour luminaire sous rampeP/N: 15735AZT/BBR/CO, 15736AZT/BBR/CO, 15755AZT/BBR/CO

Příbuzné modely 15736 | 15755 |

Komentáře k této Příručce

Žádné komentáře